You searched

omega green gas leak

Showing 1 - 40 of 68 results
Sort:
A modern, slim, space-saving design, the White Genesis Drinks Maker includes a aluminium gas cylinder and one… more info
$59.95
+ Shipping
The Omega 600mm Gas Cooktop shouts Omega’s nuanced balance of style and function, with its stainless steel finish, cast… more info
$499.00
+ Shipping
Perfect for any busy chef, this 90cm 6 Burner Gas Cooktop in black from Omega will change the way you prepare food in… more info
$1,599.00
+ Shipping
Piezoresistif sensor, hold-min-max functions, adjustable automatic shut-off, adjustable backlight, self calibration.… more info
$1,179.00
+ Shipping
The testo 316-1 gas leak detector quickly detects even the smallest leaks. Flexible measurement probe for inaccessible… more info
$599.00
+ Shipping
Green Essentials Stainless Steel Snack Pot (500ml, 1 pack) is a simple but elegant leak-proof food jar that's… more info
$16.95
+ Shipping
Green Essentials Stainless Steel Snack Pot (1 Pack) is a simple but elegant leak-proof food jar that's plastic-free. It… more info
$14.95
+ Shipping
HYELEC MS6310 Portable Flammable Combustible Gas Leak Tester with Sound and Light Alarm more info
$48.63
FREE shipping
$29.95 with FAST & FREE next day delivery* Australia wide! Includes cone hat. BUY funny party outfits at… more info
$29.95
FREE shipping
BSIDE EGD01 Combustible Flammable Gas Detector Leak Tester with LED Sound Alarm more info
$39.13
+ Shipping
HYELEC MS6310 Multifunctional Flammable Combustible Gas Leak Detector Sound Light Alarm more info
$41.66
+ Shipping
OG91XA Brand New in Box Omega 90cm Italian Made Stainless Steel Gas Cooktop 2 Years Warranty Only from Electro Seconds Factory Outlet more info
34%
Off
$629.95
+ Shipping
OG92XA Brand New in Box Omega 90cm Italian Made Stainless Steel Gas Cooktop 2 Years Warranty Only from Electro Seconds Factory Outlet more info
17%
Off
$1,249.95
+ Shipping
Free Shipping - Fast Delivery - Best Price Guaranteed - 24/7 Enquiry Line more info
$275.00
FREE shipping
Free Shipping - Fast Delivery - Best Price Guaranteed - 24/7 Enquiry Line more info
$219.00
FREE shipping
Portable Multifunctional Flammable Gas Detector Combustible Gas Leak Tester 10-40 Sound Light Alarm Adjustable… more info
$79.00
+ Shipping: $9.92
Please contact your local store for details on this product more info
$99.00
FREE shipping
Omega - 90cm 5 Burner Gas Cooktop, Stainless Steel Only from 2ndsworld.com.au more info
$1,199.00
+ Shipping
Omega - 60cm Gas Cooktop, Stainless Steel Only from 2ndsworld.com.au more info
$349.00
+ Shipping
Brentwood Walnut Timber Gas Lift Bar Stool with Fabric Seat - Green more info
$189.00
+ Shipping
A great leak proof lunchbox or storage container with stainless steel base and BPA free snap lock lid. more info
10%
Off
$14.35
+ Shipping
A safe, stainless steel lunchbox for even the hungriest family member! more info
10%
Off
$16.65
+ Shipping
LEAK Umbrella & Stand - Green Only from Mighty Ape more info
$29.99
+ Shipping: $4.90
Snaps are completely Leak Proof, easy to clean and Dishwasher safe. The 1700ml Jumbo size is ideal for storing food at… more info
$25.95
+ Shipping
Pack a waste-free lunch with the Goodbyn dipper set of food containers. Includes 2 dipper containers ideal for yoghurt,… more info
$8.95
+ Shipping: $9.95
Pack a waste-free lunch with the new Goodbyn food containers. BPA phthalates & lead free lunch box. more info
$3.00
+ Shipping: $9.95
The definitive guide to petroleum hydrocarbon fuel spill and leak causes, prevention, response, and cost recovery Oil… more info
$84.57
FREE shipping
Postage:$7.95 or Free Shipping See Website . Delivery:7-20 Business Days. Portable Multifunctional Flammable Gas… more info
57%
Off
$59.95
+ Shipping: $7.95
Postage:$7.95 or Free Shipping See Website . Delivery:7-20 Business Days. Flammable Combustible Gas Detector Gas Leak… more info
62%
Off
$49.95
+ Shipping: $7.95
POWER-MATE 10A - Power Meter, Energy Meter - GREEN HOUSE GAS MEASUREMENT - PM10A more info
$289.00
+ Shipping
Greens Plus, Chia Seeds, Omega 3 Superfood, 1 lb (454 g) Only from AussieWell Health more info
$52.95
FREE shipping
Greens Plus, Chia Omega 3 Energy Bar, Chocolate, 12 Bars, 59 g Each Only from AussieWell Health more info
$69.95
FREE shipping
* Detects combustible gases - Liquefied Natural Gas (LNG) and Liquefied Propane Gas (LPG) from 500 to 6500ppm * Highly… more info
$149.00
+ Shipping
Powerful, versatile and compact, this Omega 70cm 5 Burner Gas Cooktop features 5 burners with cast iron trivets and… more info
$1,429.00
+ Shipping
Cook delicious food for your family with this Omega 60cm 4 Burner Gas Cooktop in stainless steel which features 4… more info
$549.00
+ Shipping
For those seeking out the control and power of a gas cooktop The Omega Cooking Package is perfect. It includes the… more info
$998.00
+ Shipping
OG72XA Brand New in Box Omega 70cm Italian Made Stainless Steel Gas Cooktop 2 Years Warranty Only from Electro Seconds Factory Outlet more info
34%
Off
$529.95
+ Shipping
Perfect for healthy snacks on the go - Snaps close for leak proof travel. more info
10%
Off
$11.65
+ Shipping
The perfect size for picnics, leftovers or those with a big healthy appetite - naturally BPA and lead free. more info
10%
Off
$20.65
+ Shipping
Back to top

Latest Products
AIRBORNE PARTICLE COUNTER - IC-FLUKE-985From $9968
Features: Six channels and particle size range of 0.3 - 10.0 µm: Assures accurate measurements even for critical locations requiring ISO Class 5 – 9 certification Ultra-lightweight and ergonomic design: Promises easy single-hand operation in tight or awkward spaces with less operator fatigue Long battery life: Ten hours of standard-use battery life to last a full work day Large 3.5 QVGC Color display: Easy navigation and viewing with the intuitive icons and large font options 10,000 record storage: Quick access to historical data On-screen data presentation: Data can be viewed in a traditional tabular or trend graph view at the user’s preference Personalized setting and configurations: Customizable settings for the display, sample methods, and alarm settings for sample count Data export options: Download data to a PC using a USB memory stick, USB cable or Ethernet connection. No special software is required to download or view data Option password control: Confirms security when required USB/Ethernet charge cradle: Assures device is always ready to go when needed Includes: Cradle for charging and convenient USB and Ethernet communications, ENET CAT5E 7 foot cable, USB-A to MINI-B 6 foot cable, 12 V dc power supply, zero count inlet- filter, filter adapter, sample inlet protective cap, hard case, getting started manual and users manual CD Specifications: Channels: 0.3 μm, 0.5 μm, 1.0 μm, 2.0 μm, 5.0 μm, 10.0 μm Flow rate: 0.1 cfm (2.83 L/min) Light source: 775 nm to 795 nm, 90mW class 3B laser Count modes: Raw counts, #/m3, #/ft3, #/liter in Cumulative or Differential mode Counting efficiency: 50 % @ 0.3 μm; 100 % for particles > 0.45 μm (per ISO 21501) Zero count: 1 count/5 minute (JIS B9921) Concentration limits: 10 % at 4,000,000 particles per ft3 (per ISO 21501) Data storage: 10,000 records (rotating buffer) Alarms: counts, low battery, sensor fail Delay time: 0 to 24 hours Sample inlet: Isokinetic probe Security: Adminis
ADVANCED GEO EARTH GROUND TESTER, KIT - IC-FLUKE-1625-2 KITFrom $7024
Features: The Fluke 1625-2 earth ground tester is able to measure earth ground loop resistances using only clamps. With this test method, two clamps are placed around the earth ground rod and each are connected to the tester. No earth ground stakes are used at all. A known, fixed voltage is induced by one clamp and the current is measured using the second clamp. Then the tester automatically determines the resistance of the earth ground rod. This test method only works if a bonded earth ground system exists for the building or structure under test, but most are. If there is only one path to ground, like at many residential applications, the Stakeless method will not provide an acceptable value and the Fall of Potential test method must be used. With Stakeless testing, the earth ground rod does not need to be disconnected - leaving the bonded earth ground system intact during test. Gone are the days of spending time placing and connecting stakes for each earth ground rod on your system - a major time saver. You can also perform earth ground tests in places you’ve not considered before: inside buildings, power pylons, or anywhere you don’t have access to soil. Automatic Frequency Control (AFC) - identifies existing interference and chooses a measurement frequency to minimize its effect, providing more accurate earth ground value R* measurement – calculates earth ground impedance at 55 Hz to more accurately reflect the earth ground resistance that a fault-to earth ground would see Adjustable limits - for quicker testing 3- and 4-pole Fall-of-Potential, earth resistance loop testing 4-pole Soil Resistivity testing Selective earth ground rod testing using 1 clamp Stakeless earth ground rod testing using 2 clamps IP56 rated for outdoor use Rugged carrying case USB data storage and transfer Accessory kits: Stake Set for 3-Pole Measurement Stake Set for 4-Pole Measurement Cables and hardware: Ground/Earth Cable Reel 25 m (81.25 ft) Ground/Earth Cable Reel
10KV INSULATION TESTER KIT NA FC - IC-1555/KIT NA FCFrom $7562
Features: Test voltages to up 10 kV CAT III 1000 V, CAT IV 600 V safety rating Warning function alerts the user that line voltage is present and gives the voltage reading up to 600 V AC or DC for increased user safety Variable select test voltages in 50 V steps from 250 V to 1000 V, and 100 V steps above 1000 V Measurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recall Long battery life gives the user over 750 tests between charges Automatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup Guard system eliminates the effect of surface leakage current on high-resistance measurements Large digital/analog LCD for easy viewing Capacitance and leakage current measurement Ramp function for breakdown testing Resistance measurements up to 2 TΩ Timer settings up to 99 minutes for timed tests 3-year warranty Specifications: Test voltage (DC) range and accuracy 250 V 50 GΩ - Unspecified 500 V 100 GΩ - Unspecified 1000 V 200 GΩ - Unspecified 2500 V 500 GΩ - Unspecified 5000 V 1 TΩ - Unspecified 10000 V 2 TΩ - Unspecified Bar graph range: 0 to 1 TΩ (1550C) - 0 to 2 TΩ (1555) Insulation test voltage accuracy: -0 %, +10 % at 1 mA load current Induced ac mains current rejection: 2 mA maximum Charging rate for capacitive load: 5 seconds per μF Discharge rate for capacitive load: 1.5 s/μF Leakage current measurement: range: 1 nA to 2 mA/Accuracy: ± (5 % + 2 nA) Capacitance measurement range: 0.01 μF to 15.00 μF/Accuracy: ± (15 % rdg + 0.03 μF) Timer angle: 0 to 99 minutes/resolution: Setting: 1 minute, Indication: 1 second Live circuit warning: Warning range: 30 V to 660 V ac/dc, 50/60 Hz/ Voltage accuracy: ± (15 % + 2 V)
10KV MEGOHMMETER - IC-FLUKE-1555From $6811
Features: Test voltages to up 10 kV CAT III 1000 V, CAT IV 600 V safety rating Warning function alerts the user that line voltage is present and gives the voltage reading up to 600 V AC or DC for increased user safety Variable select test voltages in 50 V steps from 250 V to 1000 V, and 100 V steps above 1000 V Measurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recall Long battery life gives the user over 750 tests between charges Automatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup Guard system eliminates the effect of surface leakage current on high-resistance measurements Large digital/analog LCD for easy viewing Capacitance and leakage current measurement Ramp function for breakdown testing Resistance measurements up to 2 TΩ Timer settings up to 99 minutes for timed tests 3-year warranty Specifications: Test voltage (DC) range and accuracy 250 V 50 GΩ - Unspecified 500 V 100 GΩ - Unspecified 1000 V 200 GΩ - Unspecified 2500 V 500 GΩ - Unspecified 5000 V 1 TΩ - Unspecified 10000 V 2 TΩ - Unspecified Bar graph range: 0 to 1 TΩ (1550C) - 0 to 2 TΩ (1555) Insulation test voltage accuracy: -0 %, +10 % at 1 mA load current Induced ac mains current rejection: 2 mA maximum Charging rate for capacitive load: 5 seconds per μF Discharge rate for capacitive load: 1.5 s/μF Leakage current measurement: range: 1 nA to 2 mA/Accuracy: ± (5 % + 2 nA) Capacitance measurement range: 0.01 μF to 15.00 μF/Accuracy: ± (15 % rdg + 0.03 μF) Timer angle: 0 to 99 minutes/resolution: Setting: 1 minute, Indication: 1 second Live circuit warning: Warning range: 30 V to 660 V ac/dc, 50/60 Hz/ Voltage accuracy: ± (15 % + 2 V)
5KV INSULATION TESTER KIT NA FC - IC-1550C/KIT NA FCFrom $7029
Features: Test voltages to up 5 kV CAT III 1000 V, CAT IV 600 V safety rating Warning function alerts the user that line voltage is present and gives the voltage reading up to 600 V AC or DC for increased user safety Selectable test voltages in 50 V steps from 250 V to 1000 V, and 100 V steps above 1000 V Measurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recall Long battery life gives the user over 750 tests between charges Automatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup Guard system eliminates the effect of surface leakage current on high-resistance measurements Large digital/analog LCD for easy viewing Capacitance and leakage current measurement Ramp function for breakdown testing Resistance measurements up to 2 TΩ Timer settings up to 99 minutes for timed tests 3-year warranty Specifications: Test voltage (DC) range and accuracy 250 V 50 GΩ - Unspecified 500 V 100 GΩ - Unspecified 1000 V 200 GΩ - Unspecified 2500 V 500 GΩ - Unspecified 5000 V 1 TΩ - Unspecified Bar graph range: 0 to 1 TΩ (1550C) - 0 to 2 TΩ (1555) Insulation test voltage accuracy: -0 %, +10 % at 1 mA load current Induced ac mains current rejection: 2 mA maximum Charging rate for capacitive load: 5 seconds per μF Discharge rate for capacitive load: 1.5 s/μF Leakage current measurement: range: 1 nA to 2 mA/Accuracy: ± (5 % + 2 nA) Capacitance measurement range: 0.01 μF to 15.00 μF/Accuracy: ± (15 % rdg + 0.03 μF) Timer angle: 0 to 99 minutes/resolution: Setting: 1 minute, Indication: 1 second Live circuit warning: Warning range: 30 V to 660 V ac/dc, 50/60 Hz/ Voltage accuracy: ± (15 % + 2 V)
5KV MEGOHMMETER - IC-FLUKE-1550CFrom $6294
Features: Test voltages to up 5 kV CAT III 1000 V, CAT IV 600 V safety rating Warning function alerts the user that line voltage is present and gives the voltage reading up to 600 V AC or DC for increased user safety Selectable test voltages in 50 V steps from 250 V to 1000 V, and 100 V steps above 1000 V Measurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recall Long battery life gives the user over 750 tests between charges Automatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup Guard system eliminates the effect of surface leakage current on high-resistance measurements Large digital/analog LCD for easy viewing Capacitance and leakage current measurement Ramp function for breakdown testing Resistance measurements up to 2 TΩ Timer settings up to 99 minutes for timed tests 3-year warranty Specifications: Test voltage (DC) range and accuracy 250 V 50 GΩ - Unspecified 500 V 100 GΩ - Unspecified 1000 V 200 GΩ - Unspecified 2500 V 500 GΩ - Unspecified 5000 V 1 TΩ - Unspecified Bar graph range: 0 to 1 TΩ (1550C) - 0 to 2 TΩ (1555) Insulation test voltage accuracy: -0 %, +10 % at 1 mA load current Induced ac mains current rejection: 2 mA maximum Charging rate for capacitive load: 5 seconds per μF Discharge rate for capacitive load: 1.5 s/μF Leakage current measurement: range: 1 nA to 2 mA/Accuracy: ± (5 % + 2 nA) Capacitance measurement range: 0.01 μF to 15.00 μF/Accuracy: ± (15 % rdg + 0.03 μF) Timer angle: 0 to 99 minutes/resolution: Setting: 1 minute, Indication: 1 second Live circuit warning: Warning range: 30 V to 660 V ac/dc, 50/60 Hz/ Voltage accuracy: ± (15 % + 2 V)
ADVANCED GEO EARTH GROUND TESTER - IC-FLUKE-1625-2From $5400
Features: The Fluke 1625-2 earth ground tester is able to measure earth ground loop resistances using only clamps. With this test method, two clamps are placed around the earth ground rod and each are connected to the tester. No earth ground stakes are used at all. A known, fixed voltage is induced by one clamp and the current is measured using the second clamp. Then the tester automatically determines the resistance of the earth ground rod. This test method only works if a bonded earth ground system exists for the building or structure under test, but most are. If there is only one path to ground, like at many residential applications, the Stakeless method will not provide an acceptable value and the Fall of Potential test method must be used. With Stakeless testing, the earth ground rod does not need to be disconnected - leaving the bonded earth ground system intact during test. Gone are the days of spending time placing and connecting stakes for each earth ground rod on your system - a major time saver. You can also perform earth ground tests in places you’ve not considered before: inside buildings, power pylons, or anywhere you don’t have access to soil. Automatic Frequency Control (AFC) - identifies existing interference and chooses a measurement frequency to minimize its effect, providing more accurate earth ground value R* measurement – calculates earth ground impedance at 55 Hz to more accurately reflect the earth ground resistance that a fault-to earth ground would see Adjustable limits - for quicker testing 3- and 4-pole Fall-of-Potential, earth resistance loop testing 4-pole Soil Resistivity testing Selective earth ground rod testing using 1 clamp Stakeless earth ground rod testing using 2 clamps IP56 rated for outdoor use Rugged carrying case USB data storage and transfer
BASIC GEO EARTH GROUND TESTER, KIT - IC-FLUKE-1623-2 KITFrom $4319
Features: The Fluke 1623-2 earth ground tester is able to measure earth ground loop resistances using only clamps. With this test method, two clamps are placed around the earth ground rod and each are connected to the tester. No earth ground stakes are used at all. A known, fixed voltage is induced by one clamp and the current is measured using the second clamp. Then the tester automatically determines the resistance of the earth ground rod. This test method only works if a bonded earth ground system exists for the building or structure under test, but most are. If there is only one path to ground, like at many residential applications, the Stakeless method will not provide an acceptable value and the Fall-of-Potential test method must be used. Specifications: RA 3-Pole Ground Resistance Measurement (IEC 1557-5) Switch position: RA 3-pole Resolution: 0.001 Ω to 10 Ω Measuring range: 0.020 Ω to 19.99 kΩ Accuracy: ± (2 % rdg + 3 d) Operating error: ± (5 % rdg + 3 d) Measuring voltage: Vm = 48 V ac Short-circuit current: > 50 mA Measure frequency: 128 Hz Probe resistance (RS): Max 100 kΩ Auxiliary earth electrode resistance (RH): Max 100 kΩ RA 4-Pole Ground Resistance Measurement (IEC 1557-5) Switch position: RA 4-pole Resolution: 0.001 Ω to 10 Ω Measuring range: 0.020 Ω to 19.99 kΩ Accuracy: ± (2 % rdg + 3 d) Operating error: ± (5 % rdg + 3 d) Measuring voltage: Vm = 48 V ac Short-circuit current: > 50 mA Measure frequency: 128 Hz Probe resistance (RS + RES): Max 100 kΩ RA 3-Pole Selective Ground Resistance Measurement with Current Clamp (RA with Clamp) Switch position: RA 3-pole with clamp Resolution: 0.001 Ω to 10 Ω Measuring range: 0.020 Ω to 19.99 kΩ Accuracy: ± (7 % rdg + 3 d) Operating error: ± (10 % rdg + 5 d) Measuring voltage: Vm = 48 V ac Short-circuit current: > 50 mA Measure frequency: 128 Hz Probe resistance (RS): Max 100 k&O
AIRMETER WITH VELOCITY PROBE - IC-FLUKE-975VFrom $6177
Features: Simultaneously measures, logs, and displays temperature, humidity, CO2, and CO on a bright, backlit LCD display One-touch air flow and velocity with available probe Wet bulb and dew point temperature % of outside air calculation CO2 and CO field calibration feature Self-test function at startup Auto-backlight Automatically compensates for barometric pressure changes Min/Max/Average on all measured and calculated readings Multi-language user interface Metric or standard units Audible and visual threshold alarms Extensive discrete or continuous data logging capacity, downloadable to PC via USB interface Keypad lock for security Included FlukeView Forms® software Specifications: Temperature Range: -20 °C to 50 °C (-5 °F to 122 °F) Display resolution: 0.1 °C (0.1 °F) Accuracy: ± 0.9 °C/± 1.62°F from 40 °C to 60 °C/± 0.5 °C/± 1.00°F from 5 °C to 40 °C/± 1.1 °C/± 1.98 °F from -20 °C to 5 °C Relative humidity Range: 10 % to 90 % RH, non-condensing Display Resolution: 1% Accuracy: ± 2 % RH (10 % RH to 90 % RH) Air velocity Range: 50.0 fpm to 3000 fpm/0.25 m/sec to 15 m/sec Display Resolution: 1 fpm (0.005m/sec) Accuracy: ±4 % or 4 fpm/±4 % or 0.02 m/sec* whichever is greater *Accuracy specification only valid for velocity readings above 50 fpm. C0 Range: 0 to 500 ppm Display Resolution: 1 ppm Accuracy: ± 5 % or ± 3 ppm, whichever is greater, @ 20 °C and 50 % RH C02 Range: 0 to 5000 ppm Display Resolution: 1 ppm Accuracy: Warm up time 1 min (5 minutes for full specification) 2.75% + 75 ppm Dew point temperature Range: -44 °C to 50 °C, (-47 °F to 122 °F) Display Resolution: 0.1 °C (0.1 °F) Accuracy: ± 1 °C when temp: -20 °C to 50 °C RH: 40 % to 90 %/± 2 °C when temp: -20 °C to 50 °C RH: 20 % to 40 %/± 4 °C when RH: 10 % to 20 % Wet bulb tem
AIRMETER - IC-FLUKE-975From $5746
Features: Simultaneously measures, logs, and displays temperature, humidity, CO2, and CO on a bright, backlit LCD display Wet bulb and dew point temperature % of outside air calculation CO2 and CO field calibration feature Self-test function at startup Auto-backlight Automatically compensates for barometric pressure changes Min/Max/Average on all measured and calculated readings Multi-language user interface Metric or standard units Audible and visual threshold alarms Extensive discrete or continuous data logging capacity, downloadable to PC via USB interface Keypad lock for security Included FlukeView Forms® software Specifications: Temperature Range: -20 °C to 50 °C (-5 °F to 122 °F) Display resolution: 0.1 °C (0.1 °F) Accuracy: ± 0.9 °C/± 1.62°F from 40 °C to 60 °C/± 0.5 °C/± 1.00°F from 5 °C to 40 °C/± 1.1 °C/± 1.98 °F from -20 °C to 5 °C Relative humidity Range: 10 % to 90 % RH, non-condensing Display Resolution: 1% Accuracy: ± 2 % RH (10 % RH to 90 % RH) C0 Range: 0 to 500 ppm Display Resolution: 1 ppm Accuracy: ± 5 % or ± 3 ppm, whichever is greater, @ 20 °C and 50 % RH C02 Range: 0 to 5000 ppm Display Resolution: 1 ppm Accuracy: Warm up time 1 min (5 minutes for full specification) 2.75% + 75 ppm Dew point temperature Range: -44 °C to 50 °C, (-47 °F to 122 °F) Display Resolution: 0.1 °C (0.1 °F) Accuracy: ± 1 °C when temp: -20 °C to 50 °C RH: 40 % to 90 %/± 2 °C when temp: -20 °C to 50 °C RH: 20 % to 40 %/± 4 °C when RH: 10 % to 20 % Wet bulb temperature Range: -16 °C to 50 °C, (3 °F to 122 °F) Display Resolution: 0.1 °C, (0.1 °F) Accuracy: ± 1.2 °C when RH: 20 % to 90 % temp: -20 °C to 60 °C/± 2.1 °C when RH: 10 % to 20 % Volume flow rate (in a duct) Range: 0 to 3,965 M3/m, (0 to 140,000 cfm)