steel pipe - Compare The Best steel pipe Prices In Australia | GetPrice
You searched

steel pipe

Showing 1 - 20 of 41 results
Sort:
  1. The CDI 5400 clamps onto a pipe, with two flow-sensing probes projecting into the pipe through 3/16-in. drilled holes. It seals directly to the pipe; no cutting or welding is required for installation. Because each flowmeter is made and calibrated for a specific size of pipe, the digital display indicates flow directly, with no setup or adjustment. The meter measures flow by maintaining one probe warmer than the other. It determines the mass flow rate from the amount of heat required. The flow rate, in scfm or equivalent units, is shown on a large, four-digit display; a 4-20 mA output and a pulse output permit remote dis-play, totalizing and data collection. Features: - Easy to install- No moving parts- Weather resistant and surge protected (new with Rev. 3)- Milliamp output- Pulse output convertible to threshold output- User-configurable scaling, filtering and units of measure- Optional RS-485 output for networking- Housing rotates to suit vertical or horizontal installationSpecifications: - Accuracy: 5 percent of reading plus 1 percent of range for flows from 10 percent to 100 percent of indicated range at air temperatures between 20 and 120 degrees Fahrenheit- Fluids: Compressed air and Nitrogen- Range: 600 scfm- Operating pressure: 200 psig maximum on Sch. 40 steel and on Type L Copper below three inch; consult CDI for other materi-als and higher pressures.- Input power: 250 mA at 24 Vdc- Output resistance: 600 Ohms max.- Materials exposed to measured fluid: Stainless steel, gold, thermal epoxy and Viton (seal)- Ring material: Aluminum- Display: Four-digit LED display- Response time: One second to 63 percent of change in value at flows above 30 percent of range

    $1,267.20
    FREE shipping
  2. The CDI 6200 series was designed for monitoring the flow rate of compressed air systems. The flowmeter clamps onto a pipe, with two flow-sensing probes projecting into the pipe through 3/16-in. drilled holes. It seals directly to the pipe; no cutting or welding is required for installation. Because each flowmeter is made and calibrated for a specific size of pipe, the display indicates flow directly, with no setup or adjustment. The meter measures flow by maintaining one probe warmer than the other. It calculates the mass velocity from the amount of heat required, and then calculates the flow on the basis of pipe area. The flow rate, in scfm, is shown on a large, four-digit display; a 4-20 mA output and a pulse output permit remote display, totalizing and data collection. Features: - Easy to install - Housing and display rotate to suit piping orientation - IP-66 rating; suitable for wet locations - Milliamp and pulse outputs - Optional RS-485 output for networking Specifications: - Accuracy: 5 percent of reading plus 1 percent of range for flows from 10 percent to 100 percent of indicated range at air temperatures between 20 and 120 degrees Fahrenheit. - Fluids: Compressed Air, Nitrogen - Range: 200 scfm - Operating Pressure (steel and copper): 200 psig maximum - Input power: 250 mA at 24 Vdc - Output resistance: 400 Ohms max. - Exposed Materials: Stainless steel, gold, thermal epoxy and Viton (seal) - Display: Four-digit LED display - Response time: One second to 63 percent of change in value at flows above 30 percent of range

    $1,087.90
    FREE shipping
  3. Stainless Steel Pipe Wall Shelf. 900 W x 300 D x 300 H mm (shelf and bracket). 1.2 mm material 304 grade stainless steel pipe shelf. Stainless steel bracket. Specially designed for quick and easy assembly. Arrives flat packed.

    $129.00
    + Shipping
  4. Stainless Steel Pipe Wall Shelf. 1500 W x 300 D x 300 H mm (shelf and bracket). 1.2 mm material 304 grade stainless steel pipe shelf. Stainless steel bracket. Specially designed for quick and easy assembly. Arrives flat packed.

    $182.00
    + Shipping
  5. Sleek and durable, the Jura Milk Pipe with Stainless Steel Casing lets you connect your compatible milk container to the milk spout and securely transfer milk while adding an elegant touch to your coffee machine's look. Shop with Confidence, Quality Products from Leading Brands

    $29.00
    + Shipping
  6. First released in 2006 and made from extruded aluminium, the Tom Dixon Pipe Lights are a combination of contrasts with their matt powder coated exterior and shining anodised inside finish.
Because of their sleek, stylised design, they work well as a feature in any room, even without the light turned on.

    23%
    Off
    $122.00
    FREE shipping
  7. First released in 2006 and made from extruded aluminium, the Tom Dixon Pipe Lights are a combination of contrasts with their matt powder coated exterior and shining anodised inside finish.

    23%
    Off
    $122.00
    FREE shipping
  8. Wesco Stainless Steel Knife Pipe Set, Red

    33%
    Off
    $199.00
    + Shipping
  9. Wesco Stainless Steel Knife Pipe Set, Lemon Yellow

    33%
    Off
    $199.00
    + Shipping
  10. Mastrad of Paris Set of 26 Stainless Steel Pastry Tips / Piping Nozzles Compatible with all types of pastry bags Assorted with 26 straight, serrated, tapered, and narrow pastry tips Rigid and robust Made out of 100% Stainless steel Come with a box for convenient storage

    42%
    Off
    $34.99
    + Shipping
  11. Right Front Steel Brake Pipe suitable for Hilux LN106 RN105 4WD 1988-97 GenuineThis part is a Genuine Toyota steel brake pipe Suits Hilux LN106 and RN105 built from 8/1988 to 7/1997 This pipe fits between the disc brake caliper and the flexible hose on the right hand, or drivers side front wheel brake Part number for reference: 47341-35120 47341-35120 4734135120 Right Front Steel Brake Pipe suitable for Hilux LN106 RN105 4WD 1988-97 Genuine

    $10.00
    + Shipping
  12. Front Left Steel Brake Pipe suitable for Hilux LN106 RN105 GenuineThis is a new Left Hand Front (Passengers Side) Steel Brake Pipe to suit Toyota Hilux from 1989-1997 with Front Leaf SuspensionModels include LN106 RN105 YN105This is a Genuine Toyota partPart number for reference: 47343-35120 47343-35120 Front Left Steel Brake Pipe suitable for Hilux LN106 RN105 Genuine

    $10.00
    + Shipping: $11.50
  13. The secret to getting jam into the centre of doughnuts or the cream into profiteroles, this little piping tube will ensure a neat, clean filling every time. Used with one of our Icing Bags, itll make such a difference when preparing profiteroles for our Croquembouche Mould Stainless steel.

    $4.95
    + Shipping
  14. The CDI 6200 series was designed for monitoring the flow rate of compressed air systems. The flowmeter clamps onto a pipe, with two flow-sensing probes projecting into the pipe through 3/16-in. drilled holes. It seals directly to the pipe; no cutting or welding is required for installation. Because each flowmeter is made and calibrated for a specific size of pipe, the display indicates flow directly, with no setup or adjustment. The meter measures flow by maintaining one probe warmer than the other. It calculates the mass velocity from the amount of heat required, and then calculates the flow on the basis of pipe area. The flow rate, in scfm, is shown on a large, four-digit display; a 4-20 mA output and a pulse output permit remote display, totalizing and data collection. Features: - Easy to install - Housing and display rotate to suit piping orientation - IP-66 rating; suitable for wet locations - Milliamp and pulse outputs - Optional RS-485 output for networking Specifications: - Accuracy: 5 percent of reading plus 1 percent of range for flows from 10 percent to 100 percent of indicated range at air temperatures between 20 and 120 degrees Fahrenheit. - Fluids: Compressed Air, Nitrogen - Range: 200 scfm - Operating Pressure (steel and copper): 200 psig maximum - Input power: 250 mA at 24 Vdc - Output resistance: 400 Ohms max. - Exposed Materials: Stainless steel, gold, thermal epoxy and Viton (seal) - Display: Four-digit LED display - Response time: One second to 63 percent of change in value at flows above 30 percent of range

    $1,182.50
    FREE shipping
  15. The CDI 6200 series was designed for monitoring the flow rate of compressed air systems. The flowmeter clamps onto a pipe, with two flow-sensing probes projecting into the pipe through 3/16-in. drilled holes. It seals directly to the pipe; no cutting or welding is required for installation. Because each flowmeter is made and calibrated for a specific size of pipe, the display indicates flow directly, with no setup or adjustment. The meter measures flow by maintaining one probe warmer than the other. It calculates the mass velocity from the amount of heat required, and then calculates the flow on the basis of pipe area. The flow rate, in scfm, is shown on a large, four-digit display; a 4-20 mA output and a pulse output permit remote display, totalizing and data collection. Features: - Easy to install- Housing and display rotate to suit piping orientation- IP-66 rating; suitable for wet locations- Milliamp and pulse outputs- Optional RS-485 output for networking Specifications: - Accuracy: 5 percent of reading plus 1 percent of range for flows from 10 percent to 100 percent of indicated range at air temperatures between 20 and 120 degrees Fahrenheit.- Fluids: Compressed Air, Nitrogen- Range: 100 scfm- Operating Pressure (steel and copper): 200 psig maximum- Input power: 250 mA at 24 Vdc- Output resistance: 400 Ohms max.- Exposed Materials: Stainless steel, gold, thermal epoxy and Viton (seal)- Display: Four-digit LED display- Response time: One second to 63 percent of change in value at flows above 30 percent of range

    $995.50
    FREE shipping
  16. The CDI 5200 clamps onto a pipe, with two flow-sensing probes projecting into the pipe through 3/16-in. drilled holes. It seals directly to the pipe; no cutting or welding is required for installation. Because each flowmeter is made and calibrated for a specific size of pipe, the digital display indicates flow directly, with no setup or adjustment. The meter measures flow by maintaining one probe warmer than the other. It determines the mass flow rate from the amount of heat required. The flow rate, in scfm or equivalent units, is shown on a large, four-digit display; a 4-20 mA output and a pulse output permit remote dis-play, totalizing and data collection. Features: - Easy to install - Two-rings - No moving parts - Weather resistant and surge protected - Milliamp output - Pulse output convertible to threshold output - User-configurable scaling, filtering and units of measureSpecifications: - Accuracy: 5 percent of reading plus 1 percent of range for flows from 10 percent to 100 percent of indicated range at air temperatures between 20 and 120 degrees Fahrenheit.- Fluids: Compressed Air, Nitrogen - Range: 100 scfm- Operating Pressure (steel and copper): 200 psig maximum - Input power: 250 mA at 24 Vdc- Output resistance: 600 Ohms max.- Exposed Materials: Stainless steel, gold, thermal epoxy and Viton (seal)- Display: Four-digit LED display- Response time: One second to 63 percent of change in value at flows above 30 percent of range

    $891.00
    FREE shipping
  17. The CDI 5400 clamps onto a pipe, with two flow-sensing probes projecting into the pipe through 3/16-in. drilled holes. It seals directly to the pipe; no cutting or welding is required for installation. Because each flowmeter is made and calibrated for a specific size of pipe, the digital display indicates flow directly, with no setup or adjustment. The meter measures flow by maintaining one probe warmer than the other. It determines the mass flow rate from the amount of heat required. The flow rate, in scfm or equivalent units, is shown on a large, four-digit display; a 4-20 mA output and a pulse output permit remote dis-play, totalizing and data collection. Features: - Easy to install - No moving parts - Weather resistant and surge protected (new with Rev. 3) - Milliamp output - Pulse output convertible to threshold output - User-configurable scaling, filtering and units of measure - Optional RS-485 output for networking - Housing rotates to suit vertical or horizontal installation Specifications: - Accuracy: 5 percent of reading plus 1 percent of range for flows from 10 percent to 100 percent of indicated range at air temperatures between 20 and 120 degrees Fahrenheit - Fluids: Compressed air and Nitrogen - Range: 800 scfm - Operating pressure: 200 psig maximum on Sch. 40 steel and on Type L Copper below three inch; consult CDI for other materi-als and higher pressures. - Input power: 250 mA at 24 Vdc - Output resistance: 600 Ohms max. - Materials exposed to measured fluid: Stainless steel, gold, thermal epoxy and Viton (seal) - Ring material: Aluminum - Display: Four-digit LED display - Response time: One second to 63 percent of change in value at flows above 30 percent of range

    $1,641.20
    FREE shipping
  18. The CDI 5400 clamps onto a pipe, with two flow-sensing probes projecting into the pipe through 3/16-in. drilled holes. It seals directly to the pipe; no cutting or welding is required for installation. Because each flowmeter is made and calibrated for a specific size of pipe, the digital display indicates flow directly, with no setup or adjustment. The meter measures flow by maintaining one probe warmer than the other. It determines the mass flow rate from the amount of heat required. The flow rate, in scfm or equivalent units, is shown on a large, four-digit display; a 4-20 mA output and a pulse output permit remote dis-play, totalizing and data collection. Features: - Easy to install - No moving parts - Weather resistant and surge protected (new with Rev. 3) - Milliamp output - Pulse output convertible to threshold output - User-configurable scaling, filtering and units of measure - Optional RS-485 output for networking - Housing rotates to suit vertical or horizontal installation Specifications: - Accuracy: 5 percent of reading plus 1 percent of range for flows from 10 percent to 100 percent of indicated range at air temperatures between 20 and 120 degrees Fahrenheit - Fluids: Compressed air and Nitrogen - Range: 5000 scfm - Operating pressure: 200 psig maximum on Sch. 40 steel and on Type L Copper below three inch; consult CDI for other materi-als and higher pressures. - Input power: 250 mA at 24 Vdc - Output resistance: 600 Ohms max. - Materials exposed to measured fluid: Stainless steel, gold, thermal epoxy and Viton (seal) - Ring material: Aluminum - Display: Four-digit LED display - Response time: One second to 63 percent of change in value at flows above 30 percent of range

    $3,424.30
    FREE shipping
  19. The CDI 5450 is a modified version of the 5400 model that allows installation under pressure. It incorporates two valves through which the probes pass and a muffler that collects chips from the drilling process. It takes an equal amount of installation time as our standard meters and requires no shutdown of the compressed-air system. Like all of our 5000-series meters, it measures flow by maintaining one probe warmer than the other. It deter-mines the mass flow rate from the amount of heat re-quired. The flow rate, in scfm or equivalent units, is shown on a large, four-digit display; a 4-20 mA output and a pulse output permit remote display, totalizing and data collection. Features: - No system shutdown required - Installs in minutes - Weather resistant and surge protected - Milliamp output - Pulse output convertible to threshold output - User-configurable scaling, filtering and units of measure - Optional wired or wireless output for networking - Housing rotates to suit vertical or horizontal installation Specifications: - Accuracy: 5 percent of reading plus 1 percent of range for flows from 10 percent to 100 percent of indicated range at air temperatures between 20 and 120 degrees Fahrenheit - Fluids: Compressed air and Nitrogen - Range: 1200 scfm - Operating pressure: 130 psig maximum on Sch. 40 steel - Input power: 250 mA at 24 Vdc - Output resistance: 600 Ohms max. - Materials exposed to measured fluid: Stainless steel, gold, thermal epoxy and Viton (seal) - Display: Four-digit LED display - Response time: One second to 63 percent of change in value at flows above 30 percent of range

    $2,860.00
    FREE shipping
  20. The CDI 5450 is a modified version of the 5400 model that allows installation under pressure. It incorporates two valves through which the probes pass and a muffler that collects chips from the drilling process. It takes an equal amount of installation time as our standard meters and requires no shutdown of the compressed-air system. Like all of our 5000-series meters, it measures flow by maintaining one probe warmer than the other. It deter-mines the mass flow rate from the amount of heat re-quired. The flow rate, in scfm or equivalent units, is shown on a large, four-digit display; a 4-20 mA output and a pulse output permit remote display, totalizing and data collection. Features: - No system shutdown required - Installs in minutes - Weather resistant and surge protected - Milliamp output - Pulse output convertible to threshold output - User-configurable scaling, filtering and units of measure - Optional wired or wireless output for networking - Housing rotates to suit vertical or horizontal installation Specifications: - Accuracy: 5 percent of reading plus 1 percent of range for flows from 10 percent to 100 percent of indicated range at air temperatures between 20 and 120 degrees Fahrenheit - Fluids: Compressed air and Nitrogen - Range: 6000 scfm - Operating pressure: 130 psig maximum on Sch. 40 steel - Input power: 250 mA at 24 Vdc - Output resistance: 600 Ohms max. - Materials exposed to measured fluid: Stainless steel, gold, thermal epoxy and Viton (seal) - Display: Four-digit LED display - Response time: One second to 63 percent of change in value at flows above 30 percent of range

    $5,110.60
    FREE shipping
Back to top

Recently Viewed Measuring & Other


Connect
Getprice compares prices across all of your favourite products Australia-wide, covering all major cities including Sydney, Melbourne, Perth, Canberra and Brisbane.
Getprice compares prices across Sydney, Melbourne, Perth, Canberra and Brisbane.